Resources · Support matrix
How far we support each route.
For every sector and production route we show, in one table, the supported calculation components, whether the route has been tested against an independent reference case, and the date of the last check. The routes we do not support are in the table too.
- Reference case passed9
- Partial6
- Not supported5
Statuses
Every row has a status.
The status says how the route is tested on the platform. No status means accredited verification or official acceptance.
- Reference case passedThe route's reference case was run on November 8, 2026 in a local validation environment. Installation totals, embedded emissions per product and the certificate base matched independently derived expected values within tolerance. This is not an approval, a certificate or a verifier's acceptance; the scope of the case and the limits of the route are in the row's note.
- PartialThere is no independent reference case for the route yet, so the calculation for this route has not been tested against a case. Details are in the row's note.
- Not supportedThe calculation components the route requires are not in the platform. The missing components are stated in the row's note.
Matrix
Coverage by sector and route.
Case results come from the run on November 8, 2026. When a case is run again, its row is updated.
| Sector | Route | Supported calculation components | Independent reference case | Status | Last checked |
|---|---|---|---|---|---|
| Iron & Steel | Scrap–EAF | Fuel combustion, electrode emissions; charge, scrap, alloy and limestone carbon plus product, slag and dust carbon as source streams; Annex II rule (indirect emissions not included in SEE) | GS-IS-01GS-IS-04CN 7208 39 00 · 7207 12 10 | Reference case passedAgainst independent expected values · local environment · Nov 8, 2026GS-IS-01 tests the fuel and electrode items without source streams; the product marks such a calculation as incomplete. GS-IS-04 tests the source streams.For 2026 and later periods, source streams must be entered: without them the calculation is marked incomplete, and period acceptance and reporting stop. Stock breakdown, biomass and process-level balance are out of scope. | |
| Rolling mill, purchased slab | Fuel combustion, direct embedded emissions of the slab precursor, Annex II rule (the precursor's indirect share is not carried) | GS-IS-02GS-IS-02BCN 7208 39 00 ← 7207 12 10 | Reference case passedAgainst independent expected values · local environment · Nov 8, 2026The installation is recorded under a processing label (PROC-3.16, Annex I 3.16); this is not a named CBAM route. | ||
| DRI, with pellet precursor | Fuel combustion, product carbon as a source stream, direct and indirect share of the pellet precursor (the indirect share counts towards the certificate base) | GS-IS-03CN 7203 10 00 ← 2601 12 00 | Reference case passedAgainst independent expected values · local environment · Nov 8, 2026The case contains only the product carbon stream. Pellet carbon and reactor dust were not entered: they have no official values and need analysis.For 2026 and later periods, source streams must be entered: without them the calculation is marked incomplete, and period acceptance and reporting stop. Stock breakdown, biomass and process-level balance are out of scope. | ||
| Scrap–EAF, multi-product installation | Fuel and electrode emissions, attribution of installation emissions to goods by mass (tonnes) | GS-MP-01CN 7214 20 00 · 7213 91 49 | Reference case passedAgainst independent expected values · local environment · Nov 8, 2026The case tests fuel, electrode and attribution without source streams; the product marks such a calculation as incomplete. GS-IS-04 tests the source streams.For 2026 and later periods, source streams must be entered: without them the calculation is marked incomplete, and period acceptance and reporting stop. Stock breakdown, biomass and process-level balance are out of scope. | ||
| Blast furnace–BOF | Not listed | None | Not supportedWaste gas attribution and a measurable heat model are not in the platform; mass balance is not enabled for this route either. | ||
| Smelting reduction | Not listed | None | Not supportedWaste gas attribution and a measurable heat model are not in the platform; mass balance is not enabled for this route either. | ||
| Aluminium | Primary aluminium, prebaked anode | Anode CO₂, PFC emissions (slope method), fuel combustion, Annex II rule | GS-AL-01CN 7601 10 90 | Reference case passedAgainst independent expected values · local environment · Nov 8, 2026The case uses CWPB technology. PFPB L and M parameters have been added but are not tested by this case. PFPB MW has no table value: your own measurement is needed; if measurement is not possible, the CWPB value is used with a recorded justification. | |
| Secondary aluminium and aluminium products | Not listed | None | PartialAluminium products have a processing label (PROC-3.18, Annex I 3.18); this is not a named CBAM route.Reference case planned. | ||
| Cement | Clinker, dry process | Calcination (Method A), fuel combustion, indirect emissions included in SEE | GS-CEM-01CN 2523 10 00 | Reference case passedAgainst independent expected values · local environment · Nov 8, 2026 | |
| Cement products, by clinker content | Attribution of installation emissions to goods by clinker content, indirect emissions included | GS-MP-02CN 2523 29 00 · 2523 90 00 | Reference case passedAgainst independent expected values · local environment · Nov 8, 2026 | ||
| Grinding with purchased clinker | Not listed | None | PartialReference case planned. | ||
| Fertilizers | Nitric acid | N₂O measurement (GWP 265), fuel combustion, direct and indirect share of the ammonia precursor | GS-FER-01CN 2808 00 00 ← 2814 10 00 | Reference case passedAgainst independent expected values · local environment · Nov 8, 2026 | |
| Ammonia | Not listed | None | PartialReference case planned. | ||
| Ammonium nitrate (AN) and NPK | Not listed | None | PartialReference case planned. | ||
| Urea | Not listed | None | Not supportedThe regulatory calculation method for urea is not in the platform. | ||
| Hydrogen | Steam methane reforming (SMR) | Natural gas as feedstock and fuel, Annex II rule (direct emissions only) | GS-H2-01CN 2804 10 00 | Reference case passedAgainst independent expected values · local environment · Nov 8, 2026 | |
| Electrolytic hydrogen | Not listed | None | PartialReference case planned. | ||
| Hydrogen with carbon capture | Not listed | None | Not supportedCO₂ capture and transfer are not in the platform. | ||
| Electricity | Electricity | Not listed | None | PartialReference case planned. | |
| Cross-sector | Measurable heat, waste gases and CO₂ transfer | Not listed | None | Not supportedThese flows are not taken into account in any sector. |
Iron & Steel
Scrap–EAF
Reference case passedAgainst independent expected values · local environment · Nov 8, 2026GS-IS-01 tests the fuel and electrode items without source streams; the product marks such a calculation as incomplete. GS-IS-04 tests the source streams.For 2026 and later periods, source streams must be entered: without them the calculation is marked incomplete, and period acceptance and reporting stop. Stock breakdown, biomass and process-level balance are out of scope.- Supported calculation components
- Fuel combustion, electrode emissions; charge, scrap, alloy and limestone carbon plus product, slag and dust carbon as source streams; Annex II rule (indirect emissions not included in SEE)
- Independent reference case
- GS-IS-01GS-IS-04CN 7208 39 00 · 7207 12 10
- Last checked
Rolling mill, purchased slab
Reference case passedAgainst independent expected values · local environment · Nov 8, 2026The installation is recorded under a processing label (PROC-3.16, Annex I 3.16); this is not a named CBAM route.- Supported calculation components
- Fuel combustion, direct embedded emissions of the slab precursor, Annex II rule (the precursor's indirect share is not carried)
- Independent reference case
- GS-IS-02GS-IS-02BCN 7208 39 00 ← 7207 12 10
- Last checked
DRI, with pellet precursor
Reference case passedAgainst independent expected values · local environment · Nov 8, 2026The case contains only the product carbon stream. Pellet carbon and reactor dust were not entered: they have no official values and need analysis.For 2026 and later periods, source streams must be entered: without them the calculation is marked incomplete, and period acceptance and reporting stop. Stock breakdown, biomass and process-level balance are out of scope.- Supported calculation components
- Fuel combustion, product carbon as a source stream, direct and indirect share of the pellet precursor (the indirect share counts towards the certificate base)
- Independent reference case
- GS-IS-03CN 7203 10 00 ← 2601 12 00
- Last checked
Scrap–EAF, multi-product installation
Reference case passedAgainst independent expected values · local environment · Nov 8, 2026The case tests fuel, electrode and attribution without source streams; the product marks such a calculation as incomplete. GS-IS-04 tests the source streams.For 2026 and later periods, source streams must be entered: without them the calculation is marked incomplete, and period acceptance and reporting stop. Stock breakdown, biomass and process-level balance are out of scope.- Supported calculation components
- Fuel and electrode emissions, attribution of installation emissions to goods by mass (tonnes)
- Independent reference case
- GS-MP-01CN 7214 20 00 · 7213 91 49
- Last checked
Blast furnace–BOF
Not supportedWaste gas attribution and a measurable heat model are not in the platform; mass balance is not enabled for this route either.- Supported calculation components
- Not listed
- Independent reference case
- None
- Last checked
Smelting reduction
Not supportedWaste gas attribution and a measurable heat model are not in the platform; mass balance is not enabled for this route either.- Supported calculation components
- Not listed
- Independent reference case
- None
- Last checked
Aluminium
Primary aluminium, prebaked anode
Reference case passedAgainst independent expected values · local environment · Nov 8, 2026The case uses CWPB technology. PFPB L and M parameters have been added but are not tested by this case. PFPB MW has no table value: your own measurement is needed; if measurement is not possible, the CWPB value is used with a recorded justification.- Supported calculation components
- Anode CO₂, PFC emissions (slope method), fuel combustion, Annex II rule
- Independent reference case
- GS-AL-01CN 7601 10 90
- Last checked
Secondary aluminium and aluminium products
PartialAluminium products have a processing label (PROC-3.18, Annex I 3.18); this is not a named CBAM route.Reference case planned.- Supported calculation components
- Not listed
- Independent reference case
- None
- Last checked
Cement
Clinker, dry process
Reference case passedAgainst independent expected values · local environment · Nov 8, 2026- Supported calculation components
- Calcination (Method A), fuel combustion, indirect emissions included in SEE
- Independent reference case
- GS-CEM-01CN 2523 10 00
- Last checked
Cement products, by clinker content
Reference case passedAgainst independent expected values · local environment · Nov 8, 2026- Supported calculation components
- Attribution of installation emissions to goods by clinker content, indirect emissions included
- Independent reference case
- GS-MP-02CN 2523 29 00 · 2523 90 00
- Last checked
Grinding with purchased clinker
PartialReference case planned.- Supported calculation components
- Not listed
- Independent reference case
- None
- Last checked
Fertilizers
Nitric acid
Reference case passedAgainst independent expected values · local environment · Nov 8, 2026- Supported calculation components
- N₂O measurement (GWP 265), fuel combustion, direct and indirect share of the ammonia precursor
- Independent reference case
- GS-FER-01CN 2808 00 00 ← 2814 10 00
- Last checked
Ammonia
PartialReference case planned.- Supported calculation components
- Not listed
- Independent reference case
- None
- Last checked
Ammonium nitrate (AN) and NPK
PartialReference case planned.- Supported calculation components
- Not listed
- Independent reference case
- None
- Last checked
Urea
Not supportedThe regulatory calculation method for urea is not in the platform.- Supported calculation components
- Not listed
- Independent reference case
- None
- Last checked
Hydrogen
Steam methane reforming (SMR)
Reference case passedAgainst independent expected values · local environment · Nov 8, 2026- Supported calculation components
- Natural gas as feedstock and fuel, Annex II rule (direct emissions only)
- Independent reference case
- GS-H2-01CN 2804 10 00
- Last checked
Electrolytic hydrogen
PartialReference case planned.- Supported calculation components
- Not listed
- Independent reference case
- None
- Last checked
Hydrogen with carbon capture
Not supportedCO₂ capture and transfer are not in the platform.- Supported calculation components
- Not listed
- Independent reference case
- None
- Last checked
Electricity
Electricity
PartialReference case planned.- Supported calculation components
- Not listed
- Independent reference case
- None
- Last checked
Cross-sector
Measurable heat, waste gases and CO₂ transfer
Not supportedThese flows are not taken into account in any sector.- Supported calculation components
- Not listed
- Independent reference case
- None
- Last checked
Calculation components are listed only as far as the reference case tests them; rows without a case list no components. The case ID points to the record in the reference package. CN codes belong to the case's goods; the arrow marks the precursor.
What a reference case is
The expected value comes from the regulation, not the engine.
- Independent derivation
- Expected values are calculated separately with the formulas of IR (EU) 2025/2547 and official standard values, not by the calculation engine.
- Last run
- Run on 8 November 2026 in the product's local validation environment, through the real API. Compared: the installation's direct and indirect emission totals; direct, indirect and total embedded emissions per product; the certificate base (before free allocation). Not compared: the number of certificates, reporting rounding and functional-unit intensities (for example per kg N).
- Fictitious inputs
- Case inputs are fictitious; they contain no real customer data.
- What it is not
- A passed reference case is not a compliance approval, a certificate, an accredited verifier's opinion or Registry acceptance.
Three separate states
Checked, verified and accepted are not the same.
Data can be in three separate states, and each has a different owner. Carbonaz does only the first.
- 01
Data checked by the platform
The data has passed Carbonaz's own checks. This is not verification.
Who does itCarbonaz
- 02
Independently verified data
The data rests on independent verification by an accredited verifier. Carbonaz does not verify.
Who does itAccredited verifier
- 03
Declaration submitted to and accepted by the Registry
The declaration has been submitted to the CBAM Registry and accepted. The declarant submits it; Carbonaz does not submit to the Registry.
Who does itDeclarant
The states do not substitute for one another: a platform check is not verification, and verification is not Registry acceptance.
Let's look at your route together.
In a demo call we can review your installation's production route and goods against this table.